Home page
- DataBase: register and analyse report of user
- Assessment: Assess the user muscle function
- Diagnostic: Measure the muscles electrical activity for one and two muscles separately or simultaneously (EMG1, EMG1,2), evaluate the muscle strength and electrical activity at the same time (EMG/Press) ,measure stabilization (stabilizer Pressure)
- Treatment: Improve the condition of user muscles with kinds of exercises such as: relaxation, Sports pressure ,Tracking , Strengthening and BioStim protocols
- Stimulation: TENS, Frequency Modulation(FM), Faradic (Far), FES
Features
- Biofeedback through EMG and Pressure
- Combined therapy (combined with stimulation and feedback)
- Electro therapy (2 and 4 poles, 2 channels completely independent )
- Simultaneous therapy (by 2 different indications treated simultaneously by using electrode)
- Intelligent calibration system
- Many kinds of exercises and relaxation therapies
- Active training of the pelvic floor muscles
- Several exciting 3D games for treatment
- Patient performance analysis software
- Advanced Hardware
- Accurate EMG amplifier
- Microprocessor stimulation based Digital unit
Technical Specifications
- Number of Stimulation Channel: 2
- Number of EMG Channel: 2
- Number of Pressure Channel: 1
- Safety: Class I
- MDD Classification: IIa
- Isolation: Type BF
Technical Data
- EMG Signal Range: 0-2200 µv / 0.1 µv accuracy
- Pressure Range: 0-1000 mmHg / 0.1 mmHg accuracy
- Display: 22” Colour Touch Screen
- Weight: 32 Kg
- Dimensions: : 60*60*120 cm(L*W*H)
- Input Power: 60-65 VA
- Mains Supply: 100-240 VAC/50-60Hz
- Mains Fuses: 1 × Fast 2Amp/250V
Stimulator Specification
- 2Channel ( completely independent)
- Microprocessor Based Digital Unit: ARM Microcontrollers / Cortex M4
- Display Animated Feedback in Stimulation Protocol for User Interaction
- Adjustable ON/OFF time range 1-60sec(1sec Step accuracy)
- Adjustable Ramp time range 0-7 sec (0.5sec Step accuracy)
- Adjustable Fall time range 0-7 sec (0.5sec Step accuracy)
- Adjustable Hold time range 0-28 sec (1 sec Step accuracy)
- Adjustable Rest time range 0-99 sec (1 sec Step accuracy)
Stimulation Parameters
- Current Type: TENS (Low, Burst),NMES(Faradic, FES), DIA(FM)
- Stimulation Type: Constant Voltage (CV)
- Voltage Range: 0-150V to 1KΩ
- Treatment Frequency: 0.5-400Hz
- Treatment P.W: 50-990 us
- Treatment Intensity: 0-100 mA (0.5 mA Step Accuracy)
- Polarity: Red +/Red –
- Treatment Time: 1-60 min
Standard Accessories
- Wireless and rechargeable hand control
- EMG Electrode Cable
- Balloon Bulb Pump
- Pressure vaginal probe
- Pressure rectal probe
- EMG vaginal probe
- EMG rectal probe
- Lubricant gel
- Rehabilitation Ball pack
- Pressure Probe Hose
- Self-adhesive electrode 4×4 cm
Additional/Alternative Models
- Clinical Biofeedback - (Ouranos Model) - 3 channel
- Clinical Biofeedback - (Venus Model)
- Portable biofeedback
- Wireless Micro Ouranos model (Suitable for clinic, delivery room, home visit and sports places)
- Model M-502 (Suitable for clinic, delivery room and home visit )
- Model M-501 (Suitable for clinic, delivery room, home visit and patient companion for home exercise)
Classification and Approvals
- Safety Class: Class I, Type BF, IPX1 According to IEC 60601-1
- Classification according to the MDD 93/42 EEC: Class IIa
- EMC related group and classification: Class B Group 1
- EMC related group and classification: Class B Group 1
Standards:
- EN 60601-1:2012
- EN 60601-1-2:2014
- CISPR 11:2009+Amd1:2010
- EN 60601-1-6:2010/A1:2013
- EN 62304:2006/A1:2015
- IEC 61000-3-2:2018+AMD1:2020
- IEC 61000-3-3:2013+AMD1:2017
- IEC 61000-4-11:2020
- EN ISO 14971:2012
- EN 1041:2008/A1:2013
- EN ISO 15223-1:2016/C1:2017
- ISO 13485:2016
- Safety examination: CE 2703
Biofeedback working conditions
- Temperature: 10 to 38 degrees Celsius
- Humidity: 5% to 70%
Warranty and after- sales service
Mobtakeran Teb Sanat Sharif Company provides a 24 months warranty for the device from the date of purchase mentioned in the warranty certificate. Additionally, it undertakes to promptly repair or replace the defective products referred to the company. In order to use the service, the product should be referred to the after-sales service centre of the company.
Manufacture Address
No 9, Technology Incubator, Iran University of Science & Technology, Farjam st, Tehran, Iran
After-Sales Service Department
Al Haradi, Barka ,South Al Batinah Governorate, Oman
P.O.Box: 818 Postal code: 132